  mini is more. puls gmbh, arabellastrasse 15, 81925 munich tel. +49.(0)89.9278-244, fax: +49.(0)89.9278-199 sales@puls-power.com, http://www.puls-power.com puls does it again: practical, versatile and reliable like the silverline ? yet small like no other. miniline  mounted and connected in record time, no tools required  world-wide approvals (ul, en, csa, cb scheme) for industry and office/ home  tiny: wxhxd = 73 x 75 x 103mm  adjustable output voltage up to dc 56v  115/230v auto select input  puls overload design? (high output overload capability)  selectable single/parallel operation (jumper) with dc 48-56v / 100w ml100e105/040504 data sheet
0 8 16 24 32 40 48 56 64 012345 output current iout [a] output voltage vout [v] x input input voltage ac 100-120/220-240v (auto select), 47...63 hz (ac 85...132v / ac 184...264v, dc 220...375v, n= + and l= - ) input current <2.1a (@ ac 100v in , 100w p out ) <1a (@ ac 220v in , 100w p out ) external fusing not required, un it provides internal fuse (t3a15h, not accessible) transient immunity transient resi stance acc. to vde 0160 / w2 (750v/ 1.3 ms), over entire load range hold-up time (see diagram below) >40 ms @ ac 230v, 48v / 2.1a >20 ms @ ac 196v, 48v / 2.1a >20 ms @ ac 100v, 48v / 2.1a x efficiency, reliability efficiency losses typ. 91% (ac 230v, 48v / 2.1a) (see also diagram below) typ. 10w (ac 230v, 48v / 2.1a) mtbf (reliability) appr. 500.000 h acc. to siemensnorm sn 29500 48v / 2.1a, ac 230v, t amb = +40 c) prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure:  run-in / burn-in (full load, t amb = +60c, on/off cycle)  functional test (100 %) x construction, mechanics, installation robust plastic housing (us patent no. d442, 923s), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), ip20 dimensions and weight  w x h x d weight 73 mm x 75 mm x 103 mm (+ din rail) depth incl. terminals: 98 mm (+ din rail) 360 g mounting orientation , or (cf. ?output?) ventilation/cooling  free space f. cooling normal convection, no fan required recom?d.: 25mm on sides with ventilation grid easy snap-on mounting onto the din-rail (ts35/7,5 or ts35/15). unit sits safely and firmly on the rail; no tools required even to remove connection by spring clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free: 2 terminals per output connector size range  flexible cable  solid cable  wire strip length 0.3-2.5mm 2 (28-12 awg) 0.3-4mm 2 (28-12 awg) ferrules admissible 6mm (0.24in) recommended design details ? for your advantage:  all terminals are easy to reach as mounted on the front panel.  input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up. ? mounting and connection do not require any screwdriver easy, quick, durable and reliable installation. x diagrams 83 84 85 86 87 88 89 90 91 92 93 0,5 0,75 1 1,25 1,5 1,75 2 2,1 output current iout [a] efficiency [%] 230 vacin 115 vacin 0 20 40 60 80 100 120 -10 0 10 20 30 40 50 60 70 ambient temperature [c] output power [w] 0 20 40 60 80 100 120 140 160 80 120 160 200 240 280 input voltage vacin [v] hold-up time [ms] pout=100w, typ. pout=100w, min. pout=50w, typ. pout=50w, min. output characteristic v out /i out (min.) efficiency hold-up time with acin (@ v out = 48v, typ.) (at v out = 48v, typ. + min.) derating of output power mounting 85-132 v acin a-a a-b a-b 185-264 v acin a-a a-b a-b 220-375 v dcin a-a a-b a-b a b a x output output voltage  preset dc 48-56v (adj. by front panel potentiometer) 48v 0.5% @ 2.1a voltage regulation stat. <1% v out (jumper in pos. 'single use') stat. <3% v out (jumper in pos. 'parallel use'), dyn. 1.5% v out over all ripple/noise <50mv pp (20 mhz bandw., 50 ? measurem.) overvoltage prot. (ovp) <60v rated continuous loading up to 2.1a @ 48v / 1.8a @ 56v (convection cool- ing), depending on built-in orientation, v in and t amb for details see derating diagram below overload behaviour puls overload design?: no switch-off at overload/short-circuit, instead: up to 1.9 ? i rated. so you need no oversi zing to start awkward loads. protection unit is protected against (also permanent) short- circuit, overload and open-circuit. derating depending on built-in orientation; see diagram below parallel operation yes (selectable by front panel jumper) power back immunity 63v operating indicator green led x environmental data, emc, safety ambient temperature range (measured 25 mm below unit)  storage/transport  operation -25c ... +85c -10c ... +70c (for dera ting see diagram below) humidity max. 95% (without condensation) electromagnetic emissions (eme) en 61000-6-3 (includes en 61000-6-4) class b (en 55011, en 55022) en 61000-3-2 (pfc) electromagnetic immunity (emi) en 61000-6-2 (includes en 61000-6-1) safe low voltage: prot. class/degree: selv (en 60950, vde0100/t.410), pelv (en 50178) class 1 (en 60950) / ip20 (en 60529) this unit fulfills all major safety approvals for eu (en 60 950, en 60204- 1, en 50178), usa (ul 60950, e137006, ul508 listed, e198865), canada (can/csa-c22.2 no 60950 [cur], can/csa-c22.2 no. 14 [cul]), cb scheme (iec 60950). technical data ml100 .105 product information (ml100e105), rev.: 4. may 2004. unless otherwis e stated, specifications are va lid for ac 230v input voltage , +25c ambient temperature, and 5 min. run-in time. they are subject to change without prior notice. puls gmbh, arabellastra?e 15, d-81925 mnchen x tel: +49.(0)89.9278-244, fax: +49.(0)89.9278-199, e-mail: sales@puls-power.com x www.puls-power.com s p r i n g c l a m p s vin = ac 115/230v vin = ac 115/230v 'single use' 'parallel use'


▲Up To Search▲   

 
Price & Availability of ML100105

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X